Products Description
General Information
VUF- Kristal 600B UF membrane is the direct equivalent, replacement, alternative, retrofit and analogue to replace Hyflux Kristal 600B K-600B (K600B) UF membrane module.
TFERV-70 ultrafiltration (UF) membrane module is a pressurized module, which is designed and manufactured for the filtration of surface water, potable water, seawater, industrial wastewater and municipal sewage. These UF modules are made of new generation PVDF hollow fiber membrane with high fouling resistance and hydrophilicity.TFERV-70 UF module is applied in new systems, as well as directly connected to existing UF systems as replacements, providing high-quality filtrate by removing suspended solids, colloids, pyrogens, bacteria, viruses and other impurities to protect downstream processes.Features
Outside-to-inside flow direction
New generation PVDF hollow fiber
Nominal pore size of 0.03 μm
Typical filtrate quality SDI ≤ 2.5, turbidity ≤ 0.1 NTU
Advantages
High tolerance for feed water
High-quality filtrate
Less energy needed by high flux
Longer service life by high fouling resistance and mechanical strength
Direct and economical module replacement
Applications
Surface water
Well water
Potable water
Municipal sewage
Industrial wastewater
Reclaimed water reuse
RO pre-treatment
Pre-treatment of seawater desalination
Module Dimensions

L | D | D1 | W | Feed | Filtrate | Concentrate |
2,130 mm (83.86 inch) | 258 mm (10.16 inch) | 216 mm (8.5 inch) | 65 mm (7.1 inch) | 1.5” FNPT | 1.5” FNPT | 1” FNPT |
Specifications
Specifications | Parameters |
Model | VUF- Kristal 600B |
Effective membrane area | 70 m² (754 ft²) |
Fiber ID/OD | 0.6/1.15 mm (0.02/0.05 inch) |
Membrane material | PVDF (Polyvinylidene Fluoride) |
Flow direction | Outside-in |
Pore size | 0.03 μm |
Bacteria removal | > 99.9999% |
Housing material | UPVC |
End caps material | UPVC |
Potting material | Epoxy resin / Polyurethane |
O-rings material | EPDM |
Dry weight | 55 KG (121 lbs) |
Wet weight filled with water | 95 KG (209 lbs) |
Operating and Cleaning Limits
Type of operation | Dead-end flow or cross flow |
Design flux (25°C) | 40-120 L/m2·h (24-71 gfd) |
Temperature | 1-40°C (34-104°F) |
Maximum feed pressure (20°C) | 2.5 bar (36.2 psi) |
Maximum trans-membrane pressure | 2 bar (29 psi) |
Backwash flux (25°C) | 80-120 L/m2·h (48-71 gfd) |
Maximum backwash pressure | 2 bar (29 psi) |
Maximum air scour feed pressure | 2.5 bar (36 psi) |
Maximum air scour flow | 4-12 Nm3/hr (2.4-7.1 scfm) |
pH continuous operation @ 25°C | 2-11 |
pH cleaning @ 25°C | 1-12 |
Maximum NaClO | 2,000 mg/L |
Maximum feed TSS | 100 ppm |
Maximum feed turbidity | 300 NTU |
Maximum feed particle size | 300 µm |
Filtrate SDI15 | ≤2.5 |
Filtrate turbidity | ≤0.1 NTU |